Customizing a state-of-the-art electronic printing process Combi-DX1 charts are the result of extensive research to
 develop the ultimate test materials.  Combi DX1 benefits include:

- Improved color stability

- Spectrophotometrically neutral grayscales

- Selected color pigments with spectral characteristics that complement real life colors, and modern camera colorimetry

- Greater flexibility enabling more different patterns

- DX-1 patterns match CamAlign front-lit chart colorimetry

Combi DX-1 Test Targets

Pattern

Chart Name

Chart #

Features

DX-1

ColorBar / GrayScale

DX-1 CG

·         DSC six vector primary colors

·         11-step crossed grayscale

·         Center 100 IRE white chip, 2 SuperWhite and true black chips

·         Hyperbolic resolution wedge up to 1200 TV LPPH (15MHz)

·         Calibration Data included

DX-1

ColorBar / GrayScale + 4

DX-1 CBGS + 4

·         DSC six vector primary colors + four skin tone patches

·         11-step crossed grayscale

·         Center 100 IRE white chip, 2 SuperWhite and true black chips

·         Hyperbolic resolution wedge up to 1200 TV LPPH (15MHz)

·         Calibration Data included

 

DX-1

ChromaDuMonde

12

DX-1 CDM 12

·         DSC 12 vector colors

·         11-step crossed grayscale

·         Center 100 IRE white chip, 2 SuperWhite and true black chips

·         Hyperbolic resolution wedge up to 1200 TV LPPH (15MHz)

·         Calibration Data included

DX-1

ChromaDuMonde

12 + 4

DX-1 CDM 12 + 4

·         DSC 12 vector colors + four skin tone patches

·         11-step crossed grayscale

·         Center 100 IRE white chip, 2 SuperWhite and true black chips

·         Hyperbolic resolution wedge up to 1200 TV LPPH (15MHz)

·         Calibration Data included

DX-1

ChromaDuMonde

24

DX-1 CDM 24

·         DSC 24 vector colors

·         11-step crossed grayscale

·         Center 100 IRE white chip, 2 SuperWhite and true black chips

·         Hyperbolic resolution wedge up to 1200 TV LPPH (15MHz)

·         Calibration Data included

DX-1

ChromaDuMonde

28

DX-1 CDM 24 + 4

·         DSC 24 vector colors + four skin tone patches

·         11-step crossed grayscale

·         Center 100 IRE white chip, 2 SuperWhite and true black chips

·         Hyperbolic resolution wedge up to 1200 TV LPPH (15MHz)

·         Calibration Data included

DX-1

MultiBurst

DX-1 MB

·         Resolution gratings up to 1200 TV LPPH (15 MHz) for testing camera frequency response

·         Zone plates also up to 1200 TV LPPH
(15 MHz) for checking resolution characteristics and anti-aliasing

·         Also available in Black on White

DX-1

72-Db
13 Step Grayscale

DX-1

32W

·         13 step true log pattern

·         3000:1 dynamic range

·         Shows performance of your camera from the whitest white to jet black

 

DX-1

102-Db
18 Step Grayscale

DX-1

34W 

·         18 step true log pattern

·         17 f-stop dynamic range

·         Shows performance of your camera from the whitest white to jet black














































































 




Combis are easy to use . . .

. . . because they are precision "Optical Signal Generators" (OSGs) that produce waveform and vectorscope displays designed to mimic standard electronic test signals.  Featuring a "Combi"nation of test elements, Combis save time and are easier on the budget.
 

Combi-DX1 takes the guesswork out of matching video cameras!

Align multiple cameras using Combi-1's color patches and you will be delighted how simple image matching can be.  Combi-1 is especially helpful when aligning to different types of lighting, quartz, HMI, fluorescent etc.  Our aim is to give you consistent, virtually identical outputs  - every time!  Combi deviation from aim values are specified in CIE units.  Maximum tolerance for any color is 5 CIE L*U*V units, with an RMS maximum of 2 units.  As a yardstick, cameras considered "well matched" by eye, typically have a CIE color difference of 10 units.

Choose the Combi-1 that's Best for You!

 

To avoid moiré and other problems caused when typical printed patterns "beat" with a camera's CCDs, all Combi-1 and Combi-2 OSGs are produced on continuous tone or dye image films.  Mounted in shatter-proof, clearer than glass plastic, OSGs are packaged with individual calibration sheets in sturdy protective cases.

 

Uncertain which camera to buy?  Combi-DX1 can be invaluable in helping you make the best purchase decision, with confidence. 

Use with other Illuminators


While Combis are designed to be used with the
Ambi illuminator  we can supply CombiMattes to use Combi OSGs with other manufacturers' light boxes or spherical illuminators.
 

*Free shipping on all items excluding Ambi Illuminators, Stands, Maxi Charts, Maxi Cases and Super Maxi Charts